Control cable LEONI, with copper conductors, number of conductors from 1 to 61, cross-section of conductors from 1.0 mm2 to 400 mm2, with plastic insulation and sheath, AC voltage up to 1.0 kV inclusive, flame retardant when laid in a group, manufactured according to IEC 60502-1, grades:
Group 1 - Flame returdant

ng(A)-LS
NYY,
NYRY,
NYBY,
NYYRY,
NYYBY,
NYFGY,
vYY-fl,
vYYCY-fl,
vYCY-fl,
vYY(C)Y-fl,
vY(C)Y-fl,
vYY(St)Y-fl,
vY(St)Y-fl,
vYYRY-fl,
vYYBY-fl,
vYYQY-fl,
vY(St)YRY-fl,
vY(St)YBY-fl,
vY(St)YQY-fl,
YY-fl,
YYCY-fl,
YYCYRY-fl,
YCY-fl,
YY(C)Y-fl,
Y(C)Y-fl,
Y(C)YRY-fl,
YY(St)Y-fl,
Y(St)Y-fl,
YwYw-fl,
YYRY-fl,
YYBY-fl,
YYQY-fl,
Y(St)YRY-fl,
Y(St)YBY-fl,
Y(St)YQY-fl,
YwYwRYw-fl,
N2XY,
N2XRY,
N2XYRY,
N2XYBY,
v2XY-fl,
v2XYCY-fl,
v2XCY-fl,
v2XY(C)Y-fl,
v2X(C)Y-fl,
v2XY(St)Y-fl,
v2X(St)Y-fl,
v2XYRY-fl,
v2XYBY-fl,
v2XYQY-fl,
v2X(St)YRY-fl,
v2X(St)YBY-fl,
v2X(St)YQY-fl,
2XY-fl,
2XYCY-fl,
2XY(C)Y-fl,
2XCY-fl,
2X(C)Y-fl,
2X(C)Y-fl,
2XY(St)Y-fl,
2X(St)Y-fl,
2XYRY-fl,
2XYBY-fl,
2XYQY-fl,
2X(St)YRY-fl,
2X(St)YBY-fl,
2X(St)YQY-fl

Group 2 -Flame returdant, halogen free
ng(A)-HF
v2XH,
v2XHCH,
v2XCH,
v2XH(C)H,
v2X(C)H,
v2XH(St)H,
v2X(St)H,
v2XHRH,
v2XHBH,
v2XHQH,
v2X(St)HRH,
v2X(St)HBH,
v2X(St)HQH,
2XH,
2XHCH,
2XCH,
2XH(C)H,
2X(C)H,
2XH(St)H,
2X(St)H,
2XHRH,
2XHBH,
2XHQH,
2X(St)HRH,
2X(St)HBH,
2X(St)HQH.

Group 3 - Fire resistant, halogen free

ng(A)-FRHF
vHXH CI,
vHXHCH CI,
vHXCH CI,
vHXH(C)H CI,
vHX(C)H CI,
vHXH(St)H CI,
vHX(St)H CI,
vHXHRH CI,
vHXHBH CI,
vHXHQH CI,
vHX(St)HRH CI,
vHX(St)HBH CI, vHX(St)HQH CI,
HXH CI,
HXHCH CI,
HXCH CI,
HXH(C)H CI,
HX(C)H CI,
HXH(St)H CI,
HX(St)H CI,
HXHRH CI,
HXHBH CI,
HXHQH CI,
HX(St)HRH CI,
HX(St)HBH CI,
HX(St)HQH CI,
v2XH CI,
v2XHCH CI,
v2XCH CI,
v2XH(C)H CI,
v2X(C)H CI,
v2XH(St)H CI,
v2X(St)H CI,
v2XHRH CI,
v2XHBH CI,
v2XHQH CI,
v2X(St)HRH CI,
v2X(St)HBH CI,
v2X(St)HQH CI,
2XH CI,
2XHCH CI,
2XCH CI,
2XH(C)H CI,
2X(C)H CI,
2XH(St)H CI,
2XHRH CI,
2XHBH CI,
2XHQH CI,
2X(St)H CI,
2X(St)HRH CI,
2X(St)HBH CI,
2X(St)HQH CI

Group 4 - Fire resistant, halogen free

ng(A)-FRLS
vHXHCY-fl CI,
vHXH(C)Y-fl CI,
vHXH(St)Y-fl CI,
vHXHRY-fl CI,
vHXHBY-fl CI,
vHXHQY-fl CI,
vHX(St)HRY-fl CI, vHX(St)HBY-fl CI,
vHX(St)HQY-fl CI,
HXHCY-fl CI,
HXH(C)Y-fl CI,
HXH(St)Y-fl CI,
HXHRY-fl CI,
HXHBY-fl CI,
HXHQY-fl CI,
HX(St)HRY-fl CI,
HX(St)HBY-fl CI,
HX(St)HQY-fl CI,
v2XHCY-fl CI,
v2XH(C)Y-fl CI,
v2XH(St)Y-fl CI,
v2X(St)HRY-fl CI, v2X(St)HBY-fl CI, v2X(St)HQY-fl CI,
v2XHRY-fl CI,
v2XHBY-fl CI,
v2XHQY-fl CI,
2XHCY-fl CI,
2XH(C)Y-fl CI,
2XH(St)Y-fl CI,
2XHRY-fl CI,
2XHBY-fl CI,
2XHQY-fl CI,
2X(St)HRY-fl CI,
2X(St)HBY-fl CI,
2X(St)HQY-fl CI.

Ask questions by telephone or email:
+7 (921) 9530940
post@technicalsolutions.su

192242, Russia, St. Petersburg, Bela Kuna str., 1 b. 2, lit. A, office 167
Technical Solutions LLC. All rights reserved, 2021